Find Your Part
%{tishi_zhanwei}%
Get the Latest Price & Availability

Fill out the form below and our team will contact you within 30 minutes.

Submit
MPC4Mk2 VM600Mk2 Machinery Protection Processing Module
+
  • MPC4Mk2 VM600Mk2 Machinery Protection Processing Module

MPC4Mk2 VM600Mk2 Machinery Protection Processing Module

Condition:

Brand New & Original

Availability:

12-16 weeks

Delivery Time:

5-7 Days

EXW Price:

$8000

Payment:

T/T, Full Payment Before Shipping

Topteng
Product Description Technical Download
Brief Introduction
Manufacturer Vibration Monitoring
Module/Order Number MPC4Mk2  MPC4 Mk2
Description Processing Module, VM600Mk2 Machinery Protection and Condition Monitoring Card
Country of origin Switzerland
Dimension & Net Weight 26.2x18.7x2cm, 0.42kg
Packing Weight 2kg
Function & Application

The MPC4Mk2 module is a monitoring module in the Meggitt VM600Mk2 mechanical inspection system. It is always used in pairs/groups with the IOC4Mk2 module, primarily for mechanical protection and condition monitoring of rotating machinery, and can be applied in vibration monitoring and combustion monitoring. The MPC4Mk2 monitoring module is available for the VM600Mk2 system rack (ABE04x) or ultra-thin rack (ABE056). This monitoring module is a single-width module, occupying a single rack slot, and is installed on the front of the VM600Mk2 rack. The module connects directly to the rack's back panel via two connectors. System communication is primarily achieved through the Ethernet LAN connector on the module's front panel, which also allows the module to communicate with VibroSight® software on an external computer. In the VM600Mk2 rack (ABE4x), a VME bus is provided for communication between rack modules. In field applications, the IOCNMk2 input/output module is responsible for acquiring digital and analog signals transmitted from field devices. After processing, it transmits the processed data to the MPC4Mk2 monitoring module for measurement analysis and equipment status monitoring. The monitoring module then processes the acquired data and transmits it to the CPUM communication module, facilitating the VM600Mk2 control system to complete the entire mechanical protection and status monitoring process.

 

MPC4Mk2 Control Input

1. Left Button 1 is used to run the protection test of the MPC4Mk2 + IOC4Mk2 module. 

2. Right Button 2 is used to lock/unlock the MPC4Mk2 + IOC4Mk2 module and toggle the VM600Mk2 system status.

  • Locked (Safe/Reliable State) – The VM600Mk2 system performs its monitoring and protection functions while ensuring the security of the module/system and its configuration. Configuration cannot be changed, and maintenance activities cannot be performed.
  • Unlocked (Maintenance State) – The VM600Mk2 system performs its monitoring and protection functions; configuration can be changed, and maintenance activities can be performed.

3. Restart: Pressing buttons 1 and 2 simultaneously resets the MPC4Mk2 + IOC4Mk2 module and any associated RLC16Mk2 modules (VM600Mk2 system), thus restarting and performing a power-on self-test.

 

MPC4Mk2 Connectors and Status Indicators

  • CH1 to CH4: BNC connectors (female). Used to indicate the status of the dynamic channels (CH1 to CH4), transmitting buffered "raw" sensor/measurement chain analog signals from the dynamic channel inputs.
  • AX1 and AX2: BNC connectors (female). Used to indicate the status of the auxiliary channels (AX1 and AX2), transmitting buffered "raw" sensor/measurement chain analog signals from the auxiliary channel inputs.
  • J2: Acquires the corresponding digital signal.
  • LAN: 8P8C (RJ45) modular jack, female. The system Ethernet interface for communication between the MPC4Mk2 + IOC4Mk2 module and the VibroSight® software on a computer, indicating the Ethernet connection status.
  • DIAG/STATUS: Indicates the operational status of the MPC4Mk2 + IOC4Mk2 module, including whether it is running normally, its configuration status, or if there is an internal hardware or firmware failure.
    LOCK: Indicates whether the module is in a locked secure/reliable state or an unlocked maintenance state within the VM600Mk2 system.

 

The MPC4Mk2 + IOC4Mk2 mechanical protection and condition monitoring modules are designed for use with the second-generation VM600Mk2 rack-mounted mechanical monitoring system. The MPC4Mk2 is the central processing module, and the IOC4Mk2 is the input/output module. Together, these two modules provide the VM600Mk2 system with four dynamic channels and two auxiliary channels for mechanical protection, other condition monitoring, and vibration and combustion applications.

Other Information

Ordering Information

600-041 – Standard version, no CMS license, module status monitoring not enabled
600-041L – Standard version, no CMS license, with conformal coating, module status monitoring not enabled
603-041 – Standard version, pre-installed CMS license, module status monitoring enabled
600-040 – SIL version without CMS license, module status monitoring not enabled
603-040 – SIL version pre-installed CMS license, module status monitoring enabled

PNR 600-041 and 603-041 correspond to the underlying module version 600-041-vvv-vvv, where "vvv" represents the hardware version usable in the finished product. PNR 600-040 and 603-040 correspond to underlying module version 600-040-vvv-vvv, where "vvv" represents the hardware version usable in the finished product.

 

Related Products

VM600 

  • MPC4
  • IOC4T

VM600Mk2

  • ABE04x
  • ABE056
  • IOC4Mk2
  • XMV16
  • XIO16T 
  • XMC16
  • RPS6U
  • AMC10Mk2
  • IOC10Mk2
  • RLC16Mk2 
  • CPUMMk2
  • IOCNMk2

Tags:

Oct 22,2026


Head over to any generator room or industrial engine station, and you quickly learn stable speed is far more than a reading on a screen.

Oct 14,2026


Large industrial facilities host safety systems that run quietly in the background.

Oct 08,2026


When a process plant runs steady, analog input modules rarely grab anyone’s attention.

Sep 28,2026


In an industrial control system, not every important task is performed by a large controller. Sometimes, a compact I/O module is responsible for receiving the field signals that tell a control system what is happening on site.
Topteng
%{tishi_zhanwei}%

About Us

Topteng Technology Trading Co., Limited

Established in 2010, Topteng has been a leading supplier of industrial automation spare parts for decades. Specialized in PLC, DCS, ESD and TSI systems, we provide competitive pricing and expert solutions.

Address:
Units 1503-1504, Building B

No. 96-2 Lujiang Road, Siming District

Xiamen, Fujian 361001

China

Contact Us

Mob/WhatsApp/WeChat:
+86 18030030532

Follow Us

Copyright © 2025 Topteng Technology Trading Co., Limited All Rights reserved.