4351B Triconex Tricon Communication Module
4351B Triconex Tricon Communication Module
+
  • 4351B Triconex Tricon Communication Module
  • 4351B Triconex Tricon Communication Module

4351B Triconex Tricon Communication Module

Condition:

Brand New & Original

Availability:

In Stock

Delivery Time:

5-7 Days

EXW Price:

$4500

Payment:

T/T, Full Payment Before Shipping

Topteng
Product Description Technical Download
Brief Introduction
Manufacturer Triconex
Module/Order Number 4351B
Description Tricon Communication Module(TCM)
Country of origin USA
Dimension & Net Weight 40x40x3cm, 2.3kg
Packing Weight 12kg
Function & Application

The 4351B is a Tricon communication module from Triconex. This TCM is only compatible with Tricon v10.0 and later versions. The module allows Tricon to communicate with TriStation, other Tricon or Trident controllers, Modbus masters and slaves, and external hosts via Ethernet. The 4351B tricon communication module includes four serial ports, two network ports, and one debug port (for Triconex). Each serial port has a unique address and can be configured as a Modbus master or slave. Serial port 1 supports Modbus or Trimble GPS interfaces. Serial port 4 supports Modbus or TriStation interfaces. The total data rate of all four serial ports on the 4351B communication module is 460.8 kbps.

 

4351B Tricon Communication Module

 

In most process control applications, there are typically two systems to monitor and manage the process: a distributed control system (DCS) and a safety system, such as a Tricon controller. These two systems are usually isolated from each other but share a common operating interface. The Tricon controller employs a state-of-the-art microprocessor-based architecture, supporting multiple communication modes. Depending on the control program requirements, the 4351B communication module can connect to the following devices:

  • Any Modbus master, including ABB, Bailey, Fisher Rosemount, and Yokogawa DCS
  • Modbus slave devices
  • Foxboro Intelligent Automation (I/A) series Nodebus
  • Honeywell Universal Control Network (UCN)
  • Honeywell Data Highway and Local Control Network (LCN)
  • External hosts on Ethernet (802.3) networks
  • Other Triconex controllers in point-to-point, TÜV-certified networks
  • TriStation PC

 

Triconex 4351B TCM

Other Information

Tricon programs use variable names as identifiers, while Modbus devices use numeric addresses called aliases. Therefore, an alias must be assigned to each Tricon variable name that will be read or written by a Modbus device. An alias is a five-digit number representing the Modbus message type and the variable's address in Tricon. Alias ​​numbers are assigned in TriStation. Any standard Modbus device can communicate with Tricon via a TCM, provided that an alias is assigned to the Tricon variable. An alias must also be used when the host accesses Tricon through other communication modules. A single Tricon system supports a maximum of four TCMs, which must reside in two logical slots. Different TCM models cannot be mixed in the same logical slot. Each Tricon system supports a total of 32 Modbus masters or slaves—this total includes network ports and serial ports. Hot standby is not supported for TCMs, but you can replace a faulty TCM while the controller is online.

 

Specifications

Serial ports:4, RS-232/RS-485 ports, DB-9 connectors
Network ports:2, 10/100BaseT Ethernet ports, RJ-45 connectors (model 4351A and 4353);2, fiber-optic mode Ethernet ports, MTRJ connectors with 62.5/125 um fibercables (model 4352A and 4354)
Port isolation:500 VDC
Protocols: TriStation, Modbus, TCP/IP, ICMP, SNTP, TSAA, Trimble GPS, Peer-to-Peer, Peer-to-Peer Time Synchronization, Jet Direct (network printing)
Modbus functions supported:
01 — Read Coil Status 
02 — Read Input Status 
03 — Read Holding Registers 
04 — Read Input Registers 
05 — Modify Coil Status 
06 — Modify Register Content
07 — Read Exception Status
08 — Loopback Diagnostic Test
15 — Force Multiple Coils
16 — Preset Multiple Registers
Communication speed:
Copper Ethernet ports: 10/100 Mbps
Fiber Ethernet ports: 100 Mbps
Serial ports: up to 115.2 Kbps per port
Status Indicators:
PASS, FAULT, ACTIVE, FIRM
LINK— 1 per network port, TX (Transmit) — 1 per port, RX (Receive) — 1 per port

 

Related Products

4351A
4352A
4353
4354

Tags:

BLOG

Oct 08,2026

Why Does Triconex 3721 Still Matter


When a process plant runs steady, analog input modules rarely grab anyone’s attention.

Sep 28,2026

9905-971: Keeping Legacy Control Systems Connected with Reliable Discrete Input Performance


In an industrial control system, not every important task is performed by a large controller. Sometimes, a compact I/O module is responsible for receiving the field signals that tell a control system what is happening on site.

Sep 22,2026

RPS6U 200-582-500-021: Reliable Power Support Behind Industrial Monitoring


In industrial automation environments, every monitoring signal and protection function depends on a stable power foundation.

Sep 15,2026

Where Does the XIO16T 620-002-000-113 Fit in Modern Monitoring


In an industrial monitoring system, not every important component is the one doing the most visible work.
Topteng
%{tishi_zhanwei}%

About Us

Topteng Technology Trading Co., Limited

Established in 2010, Topteng has been a leading supplier of industrial automation spare parts for decades. Specialized in PLC, DCS, ESD and TSI systems, we provide competitive pricing and expert solutions.

Address:
Units 1503-1504, Building B

No. 96-2 Lujiang Road, Siming District

Xiamen, Fujian 361001

China

Contact Us

Mob/WhatsApp/WeChat:
+86 18030030532

Follow Us

Copyright © 2025 Topteng Technology Trading Co., Limited All Rights reserved.