KJ4001X1-BE1 Emerson DeltaV 8-wide I/O Carrier
Condition:
Brand New & Original
Availability:
In Stock
Delivery Time:
5-7 days
EXW Price:
$300
Payment:
T/T, Full Payment Before Shipping
The KJ4001X1-BE1 is an 8-wide I/O carrier with a shield bar for the Emerson DeltaV M-Series. It is primarily used to provide mounting space, power distribution, and LocalBus/backplane communication connections for multiple DeltaV I/O modules. It is typically used in conjunction with M-Series I/O modules such as AI/AO/DI/DO, Serial, and PROFIBUS, as well as the corresponding terminal blocks.
Main Functions
1. Mounts I/O modules
2. Provides LocalBus communication connections, serving as an interface between I/O modules and the DeltaV controller.
3. Provides field power distribution
4. The KJ4001X1-BE1 is equipped with a shield bar for connecting the shielding of field signal cables.


Role in DeltaV
The KJ4001X1-BE1 can be used with various DeltaV M-Series I/O modules, such as the KJ3221X1-BA1, KJ3222X1-BA1, KJ3223X1-BA1, KJ3203X1-BA1, KJ3241X1-BA1, and other M-Series I/O modules. The signal process is as follows:
DeltaV Controller
│ LocalBus
KJ4001X1-BE1 8-Wide I/O Carrier
│
AI AO DI DO Module
│
Terminal Blocks
│
Field Devices
| Brief Introduction | |
| Manufacturer | Emerson DeltaV |
| Module/Order Number | KJ4001X1-BE1 |
| Description | 8-wide I/O Carrier with Shield Bar |
| Country of origin | USA/Thailand/Malaysia |
| Dimension & Net Weight | 40 x 20 x 5 cm, 0.8kg |
| Packing Weight | 3kg |
FAQ
1. Are the KJ4001X1-BE1 and the Terminal Block the same product?
—No, the BE1 is a carrier and not a terminal block; when used in the field, different I/O cards require corresponding terminal blocks, which are then connected to the BE1.
2. What are some common issues with the KJ4001X1-BE1?
—The BE1 itself does not have a complex structure or functionality. Field failures typically manifest as communication errors, power supply abnormalities, shielding/grounding issues, or LocalBus Extender/Carrier connection problems.
If only one I/O module fails → check that module and its corresponding terminal block;
If multiple I/O modules fail simultaneously → check the BE1, LocalBus, power supply, and connections;
If the entire carrier has no communication → check the power supply.
Tags:
Oct 22,2026
Oct 14,2026
Oct 08,2026
Sep 28,2026
Topteng Technology Trading Co., Limited
Established in 2010, Topteng has been a leading supplier of industrial automation spare parts for decades. Specialized in PLC, DCS, ESD and TSI systems, we provide competitive pricing and expert solutions.
Address:
Units 1503-1504, Building B
No. 96-2 Lujiang Road, Siming District
Xiamen, Fujian 361001
China
Copyright © 2025 Topteng Technology Trading Co., Limited All Rights reserved.