Find Your Part
%{tishi_zhanwei}%
Get the Latest Price & Availability

Fill out the form below and our team will contact you within 30 minutes.

Submit
IS200TDBTH6A GE Mark VIe Discrete Input/Output Terminal Board
IS200TDBTH6A GE Mark VIe Discrete Input/Output Terminal Board
+
  • IS200TDBTH6A GE Mark VIe Discrete Input/Output Terminal Board
  • IS200TDBTH6A GE Mark VIe Discrete Input/Output Terminal Board

IS200TDBTH6A GE Mark VIe Discrete Input/Output Terminal Board

Condition:

Brand New & Original

Availability:

In Stock

Delivery Time:

5-7 Days

EXW Price:

$7000

Payment:

T/T, Full Payment Before Shipping

Topteng
Product Description Technical Download
Manufacturer General Electric
Module/Order Number IS200TDBTH6A
Description Mark VIe Discrete Input/Output Terminal Board
Country of origin US
Dimension & Net Weight 35x20x7cm, 1kg
Packing Weight 3kg
Function & Details

The Discrete Input/Output (TDBT) terminal block is a TMR contact input/output terminal block designed for DIN rail or flat mounting. The TDBT accepts 24 groups of isolated contact inputs supplied with standard 24V, 48V, or 125V DC voltage from an external power supply. The contact inputs feature noise suppression to prevent surge and high-frequency noise. The TDBT also provides 12 Type-C relay outputs, with relay functionality expandable via an option card.

 

The TDBT is available in three versions:

 

IS200TDBTH6A Discrete Input/Output Terminal Board

 

Contact Inputs & Relay Outputs

  1. Contact Inputs: The 48 terminals at the bottom of the terminal block are grouped as TB2. Contact wetting voltage is supplied to the board via the JE1 3-pin Mate-n-lok® connector at the bottom of the board. All wetting voltage output terminals are connected in parallel and powered by a positive voltage applied to pin 1 of the JE1. A single wetting voltage lead is allowed to connect from the board terminal to a set of remote contacts, and then the leads of each contact are returned to the input. Negative wetting voltage or return wetting voltage is provided by pin 3 of JE1. Contact input functionality and onboard signal conditioning are the same as on the STCI, scaled for 24, 48, and 125 V DC wetting voltages, respectively. Input wetting voltage ranges are 16 to 32 V DC, 32 to 64 V DC, and 100 to 145 V DC. The threshold voltage is 50% of the wetting voltage. Contact input current resistance is limited to 2.5 mA (first 21 circuits) and 10 mA (circuits 22 to 24). The 24 V DC supply on TDBTH2 uses a resettable polymer positive temperature coefficient fuse with a current limit of 0.5 A. Filters reduce high-frequency noise and suppress surges near the signal input points. Discrete input voltage signals are sent to the I/O processor, which converts them into digital signals via an opto-isolator before transmitting them to the controller.
  2. Relay Outputs: The TDBT uses pluggable terminals with connectors JW1 and JW2, supporting option board connections. The relay section of the TDBT remains unchanged across groups H2, H4, and H6; only the contact input circuitry changes. TDBT relays can be used with any specified AC or DC voltage, regardless of the board group. Without an option board, the corresponding SOL terminal for each relay is not connected. The TDBT is designed to support a rated current of 5A and a voltage gap greater than the 250V AC voltage required for all customer screws and JW1 circuitry. Relay contact ratings are a limiting factor for each application.

 

Mounting: The TDBT with a plastic insulator is mounted on a metal carrier plate, which is then mounted on a DIN rail. The TDBT with the insulator can also be mounted on a metal assembly and then bolted into a cabinet. Connections are made directly to the two sets of 48 terminals, typically using 18 AWG wire. The upper terminal group TB1 connects to the relay section of the circuit board, and the lower terminal group TB2 connects to the contact input circuit. The screw assignments for both terminal groups are the same as those on the SRLY relay board and STCI contact input terminal board. The shield should be mounted on a separate bracket.

 

The I/O processor monitors the following functions on the TDBT:

  • Monitoring contact wetting voltage. If the wetting voltage drops below 40% of the nominal voltage, a diagnostic alarm (fault) is set and locked.
  • The TDBT provides diagnostic feedback to the three PDIOs by monitoring a set of isolated contacts on each relay, indicating the status of each relay.
  • When the WROB is used with the TDBT, the isolated voltage feedback is used to detect the blown state of the six pairs of fuses on the board. The TDBT provides this feedback to all three PDIO modules.
  • Each terminal board I/O component connector has an ID device, which is read by the I/O processor. The connector ID is encoded in a read-only chip that contains the board serial number, board type, and version number. The WROB contains three ID devices, one for each PDIO. A hardware incompatibility failure will occur if there is a mismatch between the I/O components, terminal boards, or option cards.

 

IS200TDBTH6A Discrete Input/Output Terminal Board
Application

PDIO + TDBT

In the Mark VIe system, the PDIO I/O package works with the TDBT. Three I/O packages insert into D-type connectors and communicate with the controller via Ethernet. For a dual-controller system, the PDIO on TDBT connector JR1 connects to the R controller, the PDIO on JS1 connects to the S controller, and the PDIO on JT1 connects to both the R and S controllers. When using a TMR controller, each PDIO connects to the corresponding controller via a network connection.

 

IS200TDBTH6A Discrete Input/Output Terminal Board

 

TDBT + WROB

The TDBT+WROB option board IS200WROBH1A adds functionality to the TDBT, enabling it to perform the same relay circuit functions as the IS200TRLYH1B terminal board when used in a TMR system. It includes power supply for the first six relay contacts to provide fuse-induced power, and a dedicated power supply for the last relay contact. There are no jumpers or hardware settings on the TDBT. The optional board WROBH1 contains six jumpers for powering or de-energizing the relays. All six jumpers are factory-installed. When the relays are used as dry contacts and no power distribution is required, the jumpers should be removed from the board. The electrical circuitry of the IS200TDBT with the IS200WROBH1 is as follows.

 

IS200TDBTH6A Discrete Input/Output Terminal Board

 

Related Products:

IS200TDBTH2A 
IS200TDBTH2ACD 
IS200TDBTH4A 
IS200TDBTH6ABC 
IS200TDBTH6ACD

Tags:

Oct 22,2026


Head over to any generator room or industrial engine station, and you quickly learn stable speed is far more than a reading on a screen.

Oct 14,2026


Large industrial facilities host safety systems that run quietly in the background.

Oct 08,2026


When a process plant runs steady, analog input modules rarely grab anyone’s attention.

Sep 28,2026


In an industrial control system, not every important task is performed by a large controller. Sometimes, a compact I/O module is responsible for receiving the field signals that tell a control system what is happening on site.
Topteng
%{tishi_zhanwei}%

About Us

Topteng Technology Trading Co., Limited

Established in 2010, Topteng has been a leading supplier of industrial automation spare parts for decades. Specialized in PLC, DCS, ESD and TSI systems, we provide competitive pricing and expert solutions.

Address:
Units 1503-1504, Building B

No. 96-2 Lujiang Road, Siming District

Xiamen, Fujian 361001

China

Contact Us

Mob/WhatsApp/WeChat:
+86 18030030532

Follow Us

Copyright © 2025 Topteng Technology Trading Co., Limited All Rights reserved.